Differential Scanning Calorimeter

UDSC L64 - Ultimate DSC

The Ultimate DSC’s sensor delivers unmatched sensitivity for detecting minimal energy transitions.

The UDSC L64 from Calneos by Linseis is a state-of-the-art calorimeter equipped with a revolutionary sensor based on patented technology developed by one of the world’s leading DSC research laboratories. Its exceptional sensitivity allows for the detection of even the smallest thermal events – such as protein denaturation – with sample volumes as low as 5 to 100 μL.

Designed for advanced applications in biochemical, biophysical, and pharmaceutical research, the DSC L64 provides highly accurate measurements of phase transitions in liquid, gel, or solid samples. The system covers a temperature range from -60 °C to 160 °C with scan rates up to 10 °C/min, offering precise control of thermal conditions. It also enables the study of highly concentrated solutions, gels, and solids with minimal sample consumption. Thanks to extractable cells, no cleaning procedure is required, reducing downtime and improving ease of use. Automation options further enhance the system’s efficiency in both routine analysis and advanced research settings.

Whether you’re analyzing protein transitions for pharmaceutical development or investigating materials in various phases, the UDSC L64 deliver ultra-sensitive, high-performance solutions tailored to your scientific needs.

Unique Features

Zertifikat_rot
  • Ultra-sensitive, patented sensor technology
    At the heart of the UDSC L64 is a groundbreaking sensor design, developed in collaboration with one of the world’s most renowned DSC research laboratories. This patented technology enables the detection of even the smallest thermal events – such as protein denaturation – with unparalleled precision and reproducibility.
  • Minimal sample volume – only 5 to 100 μL
    The UDSC L64 requires exceptionally small amounts of sample material, making it ideal for studies involving rare, costly or limited-quantity substances like purified proteins or specialty compounds. This drastically reduces material costs and preparation time.
  • No cleaning required – extractable, sealed cells
    The system uses disposable or reusable crucibles that are easily inserted and removed. Because samples are hermetically sealed, there’s no contamination of the measuring chamber, eliminating the need for time-consuming and often unreliable cleaning procedures.
  • Fast heating rates – up to 10 °C per minute
    The DSC L64 offers rapid temperature scanning without compromising accuracy. Its unique regulation system supports heating rates of up to 10 °C/min, allowing for faster experiments and higher throughput compared to conventional DSC systems.
  • Broad temperature range from –60 °C to +160 °C*
    The system supports precise temperature control across a wide range, enabling studies of low- and mid-temperature phase transitions relevant in life sciences, pharmaceuticals and materials development.

*Depends on configuration

Versatile application for liquids, gels and solids

Whether you’re analyzing aqueous solutions, biological gels or solid-state materials, the DSC L64 handles a wide variety of sample types, making it highly flexible for diverse research and quality control needs.

With its simplified setup and standardized procedures, the DSC L64 is easily integrated into automated lab environments. This increases reproducibility and efficiency, especially in routine measurements or high-throughput screening.

The device is specifically suited for the study of protein unfolding and stability, delivering accurate measurements of denaturation temperatures and enthalpies. This makes it a valuable tool in drug development, formulation studies and biophysical characterization.

Highlights

Ultra-sensitive patented sensor

Minimal sample volume required

No cleaning procedure necessary

Broad application range

Wide temperature range

Ideal for protein research

Questions? We're just a call away!

+01 (609) 223 2070

 

+49 (0) 9287/880 0

Our service is available Monday to
Thursday from 8 am to 4 pm
and Friday from 8 am to 12 pm.

We are here for you!

Specifications

Sample volume: 5 to 100 μL

Temperature range: -60°C to 160°C*

Control accuracy: 100µ°C

Discover our ultra-sensitive DSC – designed for precision with minimal sample volume:

  • Ultra-high sensitivity for detecting minute thermal effects

  • Wide temperature range from –60 to 160 °C*

  • Extremely low ramp rates from 0.001 °C/min

  • Minimal sample volume: only 5 to 100 µL

*Depends on configuration

Operating Principle DSC L64

1. Sample preparation
The sample is prepared in sealed extractable cells (crucibles). Different types of materials are available depending on the nature of the samples being analysed. A sample crucible and a reference crucible are then placed on the
patented Ultimate DSC sensor.

2. Set-up
This sensor, which is placed in a highperformance control system (also
patented), can measure thermal effects as small as the denaturation of proteins.

3. Experiment
The temperature ramp programming over a wide temperature range (-60°C to 160°C) will allow the measurement of phase transitions of all your samples in liquid, gel, solid form etc… Thanks to its 3 high performance regulation stages, the heating rates can be programmed up to 10°C / min: a unique feature for this kind of DSC.

Software

Making values visible and comparable

The software greatly enhances your workflow as the intuitive data handling only requires minimum parameter input. AutoEval offers a valuable
guidance for the user when evaluating standard processes such as
melting and crystallization points. The optional thermal library product
identification tool, provides a database permitting an automatic identification tool for your tested polymer. Instrument control and/or surveillance through mobile devices gives you control wherever you are.

  • Software packages are compatible with latest Windows operating system
  • All specific measuring parameters (User, Lab, Sample, Company, etc.)
  • Optional password and user levels
  • Undo and redo function for all steps
  • Infinite heating, cooling or dwell time segments
  • Multiple language versions such as English, German, French, Spanish, Chinese, Japanese, Russian, etc. (user selectable)
  • The evaluation software offers a wide range of functions for the comprehensive analysis of all data types
  • Complete evaluation history (all steps can be undone)
  • Data acquisition and evaluation can be performed simultaneously
  • Data can be corrected using zero correction
  • Data evaluation includes: software signal correction and smoothing, first and second derivative, curve arithmetic, data peak evaluation, glass point evaluation, zoom, multiple curve overlay, annotation, copy to clipboard function, multiple export features for graphic and data export, automatic gas control

Application

Application example: Thermal denaturation of Lysozyme

100µL of several solutions of lysozyme in PHB buffer were placed in a 100µL crucible. Different concentrations were used, representing different masses of lysozyme analysed respectively. The reference crucible was filled with the same volume of PHB buffer. The Ultimate DSC was programmed to perform a temperature ramp from 40°C to 95°C at 1°C/min. The thermograms obtained are shown on the right.

The Ultimate DSC allows the enthalpy and denaturation temperature of Lysozyme to be measured using 5 to 10 less sample than currently available instruments. Each thermogram was obtained in less than 60 minutes, allowing rapid analysis. The Ultimate DSC saves large amounts of sample and allows you to work faster.

Application example: Thermal denaturation of RNase

Several buffered solutions of bovine RNase (50mM phosphate ph 7.3 150mM NaCl) were prepared at different concentrations. Between 50 and 80 µl of these solutions were placed in crimped measuring crucibles. The corresponding RNase masses analysed ranged from 10 to 200 µg. The reference crucible was filled with the same volume of buffer solution. The Ultimate DSC was programmed to perform a temperature ramp from 20 to 95°C at 1°C/min. The thermograms obtained are shown above. 

The Ultimate DSC allows to measure the enthalpy and denaturation temperature of bovine RNase using quantities between 200 and 10 µg, for sample volumes between 50 and 80 µl. These sample volumes used are between 5 and 10 times smaller than those usually required with currently marketed instruments, which need between 350 and 1000 µl. Each thermogram was obtained in less than 60 minutes, allowing many analyses to be carried out quickly. The Ultimate DSC saves large amounts of sample and allows faster operation. An automated version of the Ultimate DSC is also available.

Well informed

Downloads

Everything at a glance

UDSC L64 - Ultimate DSC

The Ultimate DSC’s sensor delivers unmatched sensitivity for detecting minimal energy transitions.