The Linseis HP-TGA-DSC high-pressure thermobalance / thermogravimetry opens up completely new areas of application in simultaneous thermal analysis. The system can detect both weight changes (TG) and calorific reactions (DTA/DSC) in the temperature range from RT to 1800°C and in the pressure range up to 50/150 bar.
The device is the only high-pressure STA available worldwide. A water vapour generator and complex gas controls are of course available as options. The escaping gases can be analysed at any time using a QMS or FTIR system.
This system has both an extremely high resolution and long-term drift stability. This high-pressure STA was developed to meet the demanding requirements of extremely high temperatures and extremely high pressures.
Main application of the high pressure STA:
- Pyrolysis investigations
- Gasification of coal and biomass
- Metal reduction / oxidation
Unique Features
Wide temperature
and pressure range
Simultaneous TG and
DSC/DTA measurements
High resolution
and drift stability
Versatile
gas controls
Adaptable
Service-Hotline
+1 (609) 223 2070
+49 (0) 9287/880 0
Our service is available Monday to
Thursday from 8-16 o’clock
and Friday from 8-12 o’clock.
We are here for you!
Specifications
MODEL | STA HP 1/2 |
---|---|
Temperature range: | 170°C up to 1200°C / 1600°C / 1800°C |
Vacuum: | Up to 10-4 mbar |
Max pressure: | max. 150 bar (customised solutions on request) |
Temperature precision: | 0.05°C |
TG | ||
---|---|---|
Resolution: | 0.1 μg | 0.1 μg |
Sample weight: | The scales can recognise the weight automatically | The scales can recognise the weight automatically |
Measuring range: | 25 / 2500 mg | 35000 mg |
DSC | ||
---|---|---|
DSC resolution: | 0,3 / 0,4 / 1 µW | 0,3 / 0,4 / 1 µW |
DSC sensors: | E /K / S / B / C | E /K / S / B / C |
Calorimetry sensitivity: | ca. 4 / 6 / 17.6 / 22.5 μW | ca. 4 / 6 / 17.6 / 22.5 μW |
DTA | ||
---|---|---|
DTA resolution: | 0.03 nV | 0.03 nV |
Sensitivity: | 1.5 μV / mW | 1.5 μV / mW |
DTA measuring ranges: | 250 / 2500 μV | 250 / 2500 μV |
Available accessories
- Various gas boxes: manual, semi-automatic and MFC controlled
- Water vapour generator
- Pressure control
- Wide range of crucibles (gold, silver, platinum, aluminium, Al2O3, graphite, tungsten, stainless steel (high pressure), etc.)
- Crucible press
- Various rotary and turbomolecular pumps
Sensors
Oven program
TEMPERATURE | TYPE | ELEMENT | ATMOSPHERE | TC-TYPE |
---|---|---|---|---|
-70°C – 400°C | L81/24/RCF | Hanging only, Intracooler / Kanthal | inert, oxide, red, vac. | K |
-150°C – 500°C | L81/24/500 | Kanthal | inert, oxide, red, vac. | K |
-150°C – 700°C | L81/24/700 | Kanthal | inert, oxide, red, vac. | K |
-150°C – 1000°C | L81/24/1000 | Kanthal | inert, oxide, red, vac. | K |
RT – 1200°C | L81/HF | IR heating | inert, oxide, red, vac. | S |
RT – 1000°C | L81/20AC | SiC | inert, oxide, red, vac. | K |
RT – 1600°C | L81/20AC | SiC | inert, oxide, red, vac. | S |
RT – 1750°C | L81/250 | MoSi2 | inert, oxide, vac. | B |
RT – 2000°C | L81/20/G/2000 | graphite | inert, red | C |
RT – 2400°C | L81/20/G/2400 | graphite | inert, red | Pyrometer |
RT – 2800°C | L81/20/G/2800 | graphite | inert, red | Pyrometer |
RT – 2400°C | L81/20/T | Tungsten | inert, red | C |
RT – 1000°C | L81/200 | Glow igniter | inert, oxide, red, vac. | S/K |
Software
Making values visible and comparable
The powerful LINSEIS thermal analysis software, which is based on Microsoft® Windows®, performs the most important function in the preparation, execution and evaluation of thermoanalytical experiments, in addition to the hardware used. With this software package, Linseis offers a comprehensive solution for programming all device-specific settings and control functions, as well as for data storage and evaluation. The package was developed by our in-house software specialists and application experts and has been tried and tested over many years.
General functions
- Real-time colour display
- Multi-method analysis (DSC TG, TMA, DIL, etc.)
- Programme for text editing
- Automatic and manual scaling
- Repeat measurements with minimum parameter input
- Display of axes freely selectable (e.g. temperature (x-axis) versus delta L (y-axis))
- Mathematical calculations (e.g. first and second derivative)
- Storage of complete analyses
- Multitasking function
- Multi-user function
- Zoom function for curve sections
- Curve comparison with up to 50 curves
- Online help menu
- Free labelling
- ASCII import of data
- EXCEL® and ASCII export of measurement data
- Storage of analyses
- Analysing the current measurement
- Data smoothing
- Zero curves are calculated
- Cursor function
- Statistical curve evaluation (mean value curve with confidence interval)
- Repeat measurements with minimum parameter input
- Tabular printout of data and expansion coefficients
- Calculation of Alpha Phys, Alpha Tech, relative expansion L/L0
- Curve arithmetic, addition, subtraction, multiplication
- Programmable gas control
- Data security in the event of a power failure
- Protection against thermocouple breakage
- Statistical evaluation package
- Automatic calibration
- Optional kinetics and lifetime prediction
- Software packages
TG properties:
- Percentage (%) and absolute (mg/ug) mass change
- Evaluation of the mass loss
- Determination of residual mass
- 1st and 2nd derivation (peak temperature of the mass change)
- “How to dynamic rate TGA measurement” (optional service for a fee)
HDSC features:
- Complete glass dot determination
- Specific heat Cp determination
- Multible measuring / melting points for temperature calibration
- Peak flat / enthalpy determination (different baseline types)
- Enthalpy determination taking into account the change in mass
- Determination of onset, peak, inflection point and final temperature
Applications
Application example: Hydrogen adsorption on titanium at 700°C
Activated, porous titanium surface was heated to 700°C under vacuum. At the target temperature, hydrogen was added and the pressure was increased in an isothermal step. The weight increase of the sample indicates the amount of hydrogen adsorbed on the titanium surface over the pressure, leading to saturation (2.5 % weight) at 5 bar.