{"id":100000,"date":"2024-07-23T08:46:36","date_gmt":"2024-07-23T06:46:36","guid":{"rendered":"https:\/\/www.linseis.com\/non-categorizzato\/fraunhofer-ikts-utilizza-il-dilatometro-ottico-linseis-con-atmosfere-ad-alta-purezza\/"},"modified":"2026-01-13T08:18:17","modified_gmt":"2026-01-13T07:18:17","slug":"fraunhofer-ikts-utilizza-il-dilatometro-ottico-linseis-con-atmosfere-ad-alta-purezza","status":"publish","type":"post","link":"https:\/\/www.linseis.com\/it\/ultime-notizie\/fraunhofer-ikts-utilizza-il-dilatometro-ottico-linseis-con-atmosfere-ad-alta-purezza\/","title":{"rendered":"Fraunhofer IKTS utilizza il dilatometro ottico LINSEIS con atmosfere ad alta purezza"},"content":{"rendered":"\t\t<div data-elementor-type=\"wp-post\" data-elementor-id=\"100000\" class=\"elementor elementor-100000 elementor-16791\" data-elementor-post-type=\"post\">\n\t\t\t\t<div class=\"elementor-element elementor-element-9eb8745 e-flex e-con-boxed e-con e-parent\" data-id=\"9eb8745\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-8a9139e elementor-invisible elementor-widget elementor-widget-heading\" data-id=\"8a9139e\" data-element_type=\"widget\" data-e-type=\"widget\" data-settings=\"{&quot;_animation&quot;:&quot;fadeInUp&quot;}\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Misurazione in atmosfere di elevata purezza e sotto vuoto spinto\n<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-ffaef65 elementor-invisible elementor-widget elementor-widget-text-editor\" data-id=\"ffaef65\" data-element_type=\"widget\" data-e-type=\"widget\" data-settings=\"{&quot;_animation&quot;:&quot;fadeInUp&quot;}\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Insieme al <a href=\"https:\/\/www.ikts.fraunhofer.de\/\" target=\"_blank\" rel=\"noopener\">\n  <strong>Fraunhofer IKTS<\/strong>\n<\/a> abbiamo sviluppato un <a href=\"https:\/\/www.linseis.com\/messgeraete\/dil-l74-optisches-dilatometer\/\">\n  <strong>dilatometro ottico<\/strong>\n<\/a> nell&#8217;ambito di un progetto AiF-ZIM, sostenuto dal Ministero Federale dell&#8217;Economia e dell&#8217;Energia (BMWi). <a href=\"https:\/\/www.giz.de\/de\/mit_der_giz_arbeiten\/427.html\" target=\"_blank\" rel=\"noopener\">\n  <strong>Federale per gli Affari Economici e l&#8217;Energia (BMWi)<\/strong>\n<\/a> sviluppato. Il dilatometro \u00e8 stato progettato in modo da poter misurare a temperature fino a 1600 \u00b0C e sotto vuoto spinto (circa 5 E-5 mbar). Inoltre, raggiunge un contenuto di ossigeno di circa 0,5 ppm in atmosfere dinamiche.  <\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-c9b1089 elementor-invisible elementor-widget elementor-widget-image\" data-id=\"c9b1089\" data-element_type=\"widget\" data-e-type=\"widget\" data-settings=\"{&quot;_animation&quot;:&quot;fadeInUp&quot;}\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img fetchpriority=\"high\" decoding=\"async\" width=\"300\" height=\"225\" src=\"https:\/\/www.linseis.com\/wp-content\/uploads\/2024\/07\/optical1-300x225-1.jpg\" class=\"attachment-large size-large wp-image-34198\" alt=\"\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-c96bc61 elementor-invisible elementor-widget elementor-widget-text-editor\" data-id=\"c96bc61\" data-element_type=\"widget\" data-e-type=\"widget\" data-settings=\"{&quot;_animation&quot;:&quot;fadeInUp&quot;}\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>I dilatometri ottici misurano le variazioni dimensionali dei campioni in funzione del tempo e della temperatura. Insieme ai microscopi a fase calda, hanno un&#8217;ampia gamma di applicazioni, fondamentali nello sviluppo di materiali e processi. Vengono utilizzati, ad esempio, per determinare i processi di sinterizzazione e il comportamento dell&#8217;espansione termica, soprattutto con materiali anisotropi o fragili e con campioni dalle geometrie complesse. Otticamente, il comportamento di bagnatura e diffusione su diversi substrati, attraverso l&#8217; <a href=\"https:\/\/www.linseis.com\/startseite\/messgroessen\/kontaktwinkel\/\">\n  <strong>angolo di contatto<\/strong>\n<\/a> che permette di determinare la tensione superficiale fino a temperature elevate. \u00c8 inoltre possibile analizzare la corrosione da contatto tra metallo fuso e vetro, scorie fuse e ceneri a contatto con materiali ceramici e metallici. Un&#8217;altra possibilit\u00e0 importante \u00e8 la caratterizzazione dell&#8217;infiltrazione, ad esempio di metallo fuso in materiali ceramici. I dilatometri ottici e i microscopi riscaldanti standardizzati sono progettati per misurazioni in aria o in atmosfere ad alta concentrazione di ossigeno.      <\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-5b136ef elementor-widget elementor-widget-spacer\" data-id=\"5b136ef\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"spacer.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<div class=\"elementor-spacer\">\n\t\t\t<div class=\"elementor-spacer-inner\"><\/div>\n\t\t<\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-db4a496 elementor-widget elementor-widget-spacer\" data-id=\"db4a496\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"spacer.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<div class=\"elementor-spacer\">\n\t\t\t<div class=\"elementor-spacer-inner\"><\/div>\n\t\t<\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-c8c39a6 elementor-widget elementor-widget-spacer\" data-id=\"c8c39a6\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"spacer.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<div class=\"elementor-spacer\">\n\t\t\t<div class=\"elementor-spacer-inner\"><\/div>\n\t\t<\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-1b192e5 elementor-invisible elementor-widget elementor-widget-text-editor\" data-id=\"1b192e5\" data-element_type=\"widget\" data-e-type=\"widget\" data-settings=\"{&quot;_animation&quot;:&quot;fadeInUp&quot;}\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\tIl dilatometro \u00e8 stato progettato appositamente per la caratterizzazione dei processi di giunzione di giunti ceramica-ceramica e ceramica-metallo mediante saldatura attiva. Il nuovo dilatometro ottico consente di indagare il comportamento di fusione e bagnatura su substrati ceramici di materiali di saldatura con componenti di saldatura affini all&#8217;ossigeno, come il titanio. Con i microscopi convenzionali a fase calda, si verifica un&#8217;ossidazione superficiale dovuta alla presenza di ossigeno residuo, che ostacola la bagnatura del substrato da parte della saldatura o porta a risultati falsati. Le nuove possibilit\u00e0 sperimentali ottenute in questo modo rappresentano un contributo significativo alla comprensione fondamentale e all&#8217;ulteriore sviluppo e ottimizzazione dei processi di giunzione.   \t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-7b2ae0e elementor-widget__width-initial elementor-invisible elementor-widget elementor-widget-image\" data-id=\"7b2ae0e\" data-element_type=\"widget\" data-e-type=\"widget\" data-settings=\"{&quot;_animation&quot;:&quot;fadeInUp&quot;}\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"800\" height=\"450\" src=\"https:\/\/www.linseis.com\/wp-content\/uploads\/2024\/07\/DIL-mit-Kruess-1024x576.png\" class=\"attachment-large size-large wp-image-36206\" alt=\"\" srcset=\"https:\/\/www.linseis.com\/wp-content\/uploads\/2024\/07\/DIL-mit-Kruess-1024x576.png 1024w, https:\/\/www.linseis.com\/wp-content\/uploads\/2024\/07\/DIL-mit-Kruess-300x169.png 300w, https:\/\/www.linseis.com\/wp-content\/uploads\/2024\/07\/DIL-mit-Kruess-768x432.png 768w, https:\/\/www.linseis.com\/wp-content\/uploads\/2024\/07\/DIL-mit-Kruess-1536x864.png 1536w, https:\/\/www.linseis.com\/wp-content\/uploads\/2024\/07\/DIL-mit-Kruess-2048x1152.png 2048w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-d7b829e elementor-widget elementor-widget-spacer\" data-id=\"d7b829e\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"spacer.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<div class=\"elementor-spacer\">\n\t\t\t<div class=\"elementor-spacer-inner\"><\/div>\n\t\t<\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t","protected":false},"excerpt":{"rendered":"<p>Insieme al Fraunhofer IKTS, abbiamo sviluppato un dilatometro ottico nell&#8217;ambito di un progetto AiF-ZIM finanziato dal Ministero Federale Tedesco per gli Affari Economici e l&#8217;Energia (BMWi).<\/p>\n","protected":false},"author":3,"featured_media":36206,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"inline_featured_image":false,"footnotes":""},"categories":[539],"tags":[],"class_list":["post-100000","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-ultime-notizie"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.linseis.com\/it\/wp-json\/wp\/v2\/posts\/100000","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.linseis.com\/it\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.linseis.com\/it\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.linseis.com\/it\/wp-json\/wp\/v2\/users\/3"}],"replies":[{"embeddable":true,"href":"https:\/\/www.linseis.com\/it\/wp-json\/wp\/v2\/comments?post=100000"}],"version-history":[{"count":0,"href":"https:\/\/www.linseis.com\/it\/wp-json\/wp\/v2\/posts\/100000\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.linseis.com\/it\/wp-json\/wp\/v2\/media\/36206"}],"wp:attachment":[{"href":"https:\/\/www.linseis.com\/it\/wp-json\/wp\/v2\/media?parent=100000"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.linseis.com\/it\/wp-json\/wp\/v2\/categories?post=100000"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.linseis.com\/it\/wp-json\/wp\/v2\/tags?post=100000"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}