{"id":95705,"date":"2025-08-26T08:00:00","date_gmt":"2025-08-26T06:00:00","guid":{"rendered":"https:\/\/www.linseis.com\/?p=95705"},"modified":"2025-09-02T14:41:34","modified_gmt":"2025-09-02T12:41:34","slug":"la-thermodynamique-rencontre-la-biopharmacie-pourquoi-itc-devient-de-plus-en-plus-pertinent-pour-les-laboratoires","status":"publish","type":"post","link":"https:\/\/www.linseis.com\/fr\/connaissance\/la-thermodynamique-rencontre-la-biopharmacie-pourquoi-itc-devient-de-plus-en-plus-pertinent-pour-les-laboratoires\/","title":{"rendered":"La thermodynamique rencontre la biopharmacie &#8211; Pourquoi ITC devient de plus en plus pertinent pour les laboratoires"},"content":{"rendered":"\t\t<div data-elementor-type=\"wp-post\" data-elementor-id=\"95705\" class=\"elementor elementor-95705 elementor-95686\" data-elementor-post-type=\"post\">\n\t\t\t\t<div class=\"elementor-element elementor-element-57b4747 e-flex e-con-boxed e-con e-parent\" data-id=\"57b4747\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t<div class=\"elementor-element elementor-element-8fe42cb e-con-full e-flex e-con e-child\" data-id=\"8fe42cb\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div class=\"elementor-element elementor-element-aa11874 e-con-full e-flex e-con e-child\" data-id=\"aa11874\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div class=\"elementor-element elementor-element-2c989c1 e-con-full e-flex e-con e-child\" data-id=\"2c989c1\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div class=\"elementor-element elementor-element-e6ae84c e-con-full e-flex e-con e-child\" data-id=\"e6ae84c\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div class=\"elementor-element elementor-element-8b1d688 e-con-full e-flex e-con e-child\" data-id=\"8b1d688\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-4f88904 elementor-toc--minimized-on-tablet elementor-widget elementor-widget-table-of-contents\" data-id=\"4f88904\" data-element_type=\"widget\" data-e-type=\"widget\" data-settings=\"{&quot;headings_by_tags&quot;:[&quot;h2&quot;],&quot;exclude_headings_by_selector&quot;:[],&quot;no_headings_message&quot;:&quot;No headings were found on this page.&quot;,&quot;marker_view&quot;:&quot;numbers&quot;,&quot;minimize_box&quot;:&quot;yes&quot;,&quot;minimized_on&quot;:&quot;tablet&quot;,&quot;hierarchical_view&quot;:&quot;yes&quot;,&quot;min_height&quot;:{&quot;unit&quot;:&quot;px&quot;,&quot;size&quot;:&quot;&quot;,&quot;sizes&quot;:[]},&quot;min_height_tablet&quot;:{&quot;unit&quot;:&quot;px&quot;,&quot;size&quot;:&quot;&quot;,&quot;sizes&quot;:[]},&quot;min_height_mobile&quot;:{&quot;unit&quot;:&quot;px&quot;,&quot;size&quot;:&quot;&quot;,&quot;sizes&quot;:[]}}\" data-widget_type=\"table-of-contents.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<div class=\"elementor-toc__header\">\n\t\t\t\t\t\t<h4 class=\"elementor-toc__header-title\">\n\t\t\t\tTable des mati\u00e8res\t\t\t<\/h4>\n\t\t\t\t\t\t\t\t\t\t<div class=\"elementor-toc__toggle-button elementor-toc__toggle-button--expand\" role=\"button\" tabindex=\"0\" aria-controls=\"elementor-toc__4f88904\" aria-expanded=\"true\" aria-label=\"Ouvrir la table des mati\u00e8res\"><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewBox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/div>\n\t\t\t\t<div class=\"elementor-toc__toggle-button elementor-toc__toggle-button--collapse\" role=\"button\" tabindex=\"0\" aria-controls=\"elementor-toc__4f88904\" aria-expanded=\"true\" aria-label=\"Fermer la table des mati\u00e8res\"><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewBox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<div id=\"elementor-toc__4f88904\" class=\"elementor-toc__body\">\n\t\t\t<div class=\"elementor-toc__spinner-container\">\n\t\t\t\t<svg class=\"elementor-toc__spinner eicon-animation-spin e-font-icon-svg e-eicon-loading\" aria-hidden=\"true\" viewBox=\"0 0 1000 1000\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M500 975V858C696 858 858 696 858 500S696 142 500 142 142 304 142 500H25C25 237 238 25 500 25S975 237 975 500 763 975 500 975Z\"><\/path><\/svg>\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-a92670d elementor-widget elementor-widget-spacer\" data-id=\"a92670d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"spacer.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<div class=\"elementor-spacer\">\n\t\t\t<div class=\"elementor-spacer-inner\"><\/div>\n\t\t<\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-04a345c elementor-widget elementor-widget-heading\" data-id=\"04a345c\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Introduction<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-b22fc03 elementor-widget elementor-widget-text-editor\" data-id=\"b22fc03\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Dans le d\u00e9veloppement pr\u00e9clinique de m\u00e9dicaments, tout tourne autour de la compr\u00e9hension des interactions mol\u00e9culaires. Qu&rsquo;il s&rsquo;agisse <b>de complexes prot\u00e9ine-ligand<\/b>, de <b>liaisons anticorps-antig\u00e8ne<\/b> ou <b>d&rsquo;interactions enzyme-inhibiteur<\/b>, ce qui compte pour la s\u00e9lection et l&rsquo;optimisation des substances actives biopharmaceutiques, ce n&rsquo;est pas seulement de savoir si une mol\u00e9cule se lie, mais aussi avec quelle efficacit\u00e9, quelle force et pourquoi elle se lie. <\/p><p>C&rsquo;est l\u00e0 qu&rsquo;intervient la <b>calorim\u00e9trie par titrage isotherme (ITC)<\/b>: une m\u00e9thode sans \u00e9tiquette, fonctionnant en solution, qui permet de d\u00e9terminer l&rsquo;affinit\u00e9 de liaison, <a href=\"https:\/\/www.linseis.com\/fr\/proprietes\/enthalpie\/\" data-auto-event-observed=\"true\"><strong>Enthalpie (\u0394H)<\/strong><\/a>, l&rsquo;entropie (\u0394S), l&rsquo;\u00e9nergie libre (\u0394G) et la st\u0153chiom\u00e9trie peuvent \u00eatre d\u00e9termin\u00e9es en une seule exp\u00e9rience. Elle permet de caract\u00e9riser les interactions non seulement qualitativement, mais aussi enti\u00e8rement thermodynamiquement, et ce dans des conditions quasi physiologiques.<\/p><p>L&rsquo;<b>ITC <\/b>est un outil puissant pour le personnel de laboratoire impliqu\u00e9 dans la caract\u00e9risation des produits biologiques, des peptides th\u00e9rapeutiques ou des prot\u00e9ines recombinantes. Dans les premi\u00e8res phases de criblage, elle permet d&rsquo;identifier rapidement les mol\u00e9cules actives de liaison. Plus tard, elle aide \u00e0 optimiser les formulations, \u00e0 valider les syst\u00e8mes de tampons ou \u00e0 \u00e9valuer les param\u00e8tres critiques de stabilit\u00e9.  <\/p><p>Cet article s&rsquo;adresse \u00e0 tous ceux qui travaillent en laboratoire sur des substances biopharmaceutiques, que ce soit dans des universit\u00e9s, des start-ups ou des entreprises pharmaceutiques \u00e9tablies. Nous montrons comment fonctionne l&rsquo;ITC, quand elle est sup\u00e9rieure aux autres m\u00e9thodes et ce \u00e0 quoi il faut faire attention pour tirer le meilleur parti de chaque exp\u00e9rience. <\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-2a3bb73 elementor-widget elementor-widget-heading\" data-id=\"2a3bb73\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Comment fonctionne ITC - et pourquoi cela est crucial<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-9873860 elementor-widget elementor-widget-text-editor\" data-id=\"9873860\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>La <b>calorim\u00e9trie par titrage isotherme (ITC)<\/b> est l&rsquo;une des rares m\u00e9thodes biophysiques qui mesurent directement la chaleur lib\u00e9r\u00e9e ou absorb\u00e9e lors de la liaison de deux mol\u00e9cules. Contrairement aux m\u00e9thodes spectroscopiques ou bas\u00e9es sur le marquage telles que la SPR (spectroscopie de r\u00e9sonance plasmonique de surface) ou la MST (thermophor\u00e8se \u00e0 l&rsquo;\u00e9chelle microscopique), l&rsquo;<b>ITC <\/b>fonctionne enti\u00e8rement sans \u00e9tiquette et en solution, ce qui la rend particuli\u00e8rement attrayante pour les \u00e9chantillons sensibles ou natifs. <\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-d7e2d86 elementor-widget elementor-widget-heading\" data-id=\"d7e2d86\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Que se passe-t-il dans le cylindre de mesure ?<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-30a2ec8 elementor-widget elementor-widget-text-editor\" data-id=\"30a2ec8\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Le principe est simple mais puissant : la mol\u00e9cule d&rsquo;analyte (par ex. une prot\u00e9ine) est dissoute dans une cellule calorim\u00e9trique tr\u00e8s sensible. La mol\u00e9cule de ligand (par exemple un inhibiteur ou un antig\u00e8ne) est titr\u00e9e \u00e0 l&rsquo;aide d&rsquo;une fine seringue, g\u00e9n\u00e9ralement en 10 \u00e0 20 petites injections. Chaque fois que les mol\u00e9cules se lient, de la chaleur est lib\u00e9r\u00e9e ou absorb\u00e9e. Cette chaleur est mesur\u00e9e par l&rsquo;instrument sous la forme d&rsquo;une impulsion thermique.   <\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-b4b7eba elementor-widget elementor-widget-heading\" data-id=\"b4b7eba\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Que fournit concr\u00e8tement l'ITC ?<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-b992738 elementor-widget elementor-widget-text-editor\" data-id=\"b992738\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Une courbe de liaison est calcul\u00e9e \u00e0 partir des flux de chaleur \u00e0 chaque injection. Il en r\u00e9sulte <\/p><ul><li><strong>Constante de liaison (K)<\/strong>: indique la force de la liaison.<\/li><li><strong>Changement d&rsquo;enthalpie (\u0394H)<\/strong>: indique si la liaison est exothermique ou endothermique.<\/li><li><strong>Changement d&rsquo;entropie (\u0394S)<\/strong>: donne des informations sur les changements d&rsquo;ordre dans le syst\u00e8me.<\/li><li><strong>L&rsquo;\u00e9nergie libre (\u0394G)<\/strong>: L&rsquo;expression thermodynamique combin\u00e9e de la liaison.<\/li><li><strong>Param\u00e8tres de st\u0153chiom\u00e9trie (n)<\/strong>: Combien de ligands se lient par mol\u00e9cule cible ?<\/li><\/ul><p>Ces param\u00e8tres aident non seulement \u00e0 identifier les mol\u00e9cules \u00ab\u00a0hit\u00a0\u00bb ou \u00ab\u00a0lead\u00a0\u00bb, mais fournissent \u00e9galement des informations sur le fait que la liaison est entra\u00een\u00e9e par l&rsquo;entropie ou l&rsquo;enthalpie, ce qui est crucial pour l&rsquo;optimisation ult\u00e9rieure. En combinant puissance, simplicit\u00e9 et physique directe, l&rsquo;<b>ITC <\/b>est l&rsquo;une des m\u00e9thodes les plus robustes pour caract\u00e9riser la liaison mol\u00e9culaire &#8211; en particulier l\u00e0 o\u00f9 la compr\u00e9hension des bases \u00e9nerg\u00e9tiques compte. <\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-b7e9dd8 elementor-widget elementor-widget-heading\" data-id=\"b7e9dd8\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">ITC en action : applications typiques dans le domaine biopharmaceutique<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-dfaba7a elementor-widget elementor-widget-text-editor\" data-id=\"dfaba7a\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Pour beaucoup de personnes travaillant dans des laboratoires, la question est de savoir quand l&rsquo;utilisation d&rsquo;<b>ITC <\/b>est vraiment rentable.<\/p><p>La r\u00e9ponse : chaque fois qu&rsquo;il ne s&rsquo;agit pas seulement de d\u00e9tecter des liaisons, mais de les comprendre en d\u00e9tail. Pour les questions biopharmaceutiques, la calorim\u00e9trie par titrage isotherme ne fournit pas seulement des valeurs pour les constantes de liaison, mais aussi des aper\u00e7us thermodynamiques profonds qui sont essentiels pour la caract\u00e9risation et l&rsquo;optimisation des m\u00e9dicaments. <\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-72b3d3e elementor-widget elementor-widget-heading\" data-id=\"72b3d3e\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Interactions prot\u00e9ine-ligand : Le classique<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-cca05d2 elementor-widget elementor-widget-text-editor\" data-id=\"cca05d2\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Dans la recherche pr\u00e9coce sur les substances actives, il s&rsquo;agit justement d&rsquo;identifier les partenaires de liaison, de quantifier leur affinit\u00e9 et de d\u00e9cider si une structure directrice a un potentiel. Avec l&rsquo;<b>ITC <\/b>, il est possible de : <\/p><ul><li>tester de petites mol\u00e9cules (par exemple des inhibiteurs) contre des enzymes ou des prot\u00e9ines de transport<\/li><li>\u00c9tudier les agents peptidiques et leur liaison \u00e0 la cible<\/li><li>Capter \u00e9nerg\u00e9tiquement les changements de conformation lors de la liaison<\/li><\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-6ba7a57 elementor-widget elementor-widget-heading\" data-id=\"6ba7a57\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Interactions anticorps-antig\u00e8nes : Comprendre l'affinit\u00e9, pas seulement la mesurer<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-77b32c1 elementor-widget elementor-widget-text-editor\" data-id=\"77b32c1\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>La m\u00e9thode fournit des r\u00e9sultats pour les solides et les liquides, ainsi que pour les poudres et les p\u00e2tes, avec une grande pr\u00e9cision de mesure, ce qui la rend particuli\u00e8rement pr\u00e9cieuse pour le d\u00e9veloppement de mat\u00e9riaux d&rsquo;\u00e9lectrodes innovants.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-be0b508 elementor-widget elementor-widget-heading\" data-id=\"be0b508\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Consid\u00e9rations sp\u00e9cifiques aux mat\u00e9riaux et effets du vieillissement<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-4451a72 elementor-widget elementor-widget-text-editor\" data-id=\"4451a72\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Pour le d\u00e9veloppement de produits th\u00e9rapeutiques \u00e0 base d&rsquo;anticorps, l&rsquo;<b>ITC <\/b>est un compl\u00e9ment pr\u00e9cieux :<\/p><ul><li>mesure pr\u00e9cise de l&rsquo;enthalpie et de l&rsquo;entropie de liaison (\u2192 empreintes thermodynamiques)<\/li><li>\u00c9valuation de la st\u0153chiom\u00e9trie (par ex. liaison monovalente vs. bivalente)<\/li><li>Comparaison des variants d&rsquo;anticorps natifs et modifi\u00e9s dans le tampon ou le s\u00e9rum<\/li><\/ul><p>Cela permet non seulement de s\u00e9lectionner les meilleurs candidats de liaison, mais aussi de tirer des conclusions sur les \u00e9pitopes et les m\u00e9canismes de liaison.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-e16a591 elementor-widget elementor-widget-heading\" data-id=\"e16a591\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">D\u00e9veloppement de formulations : criblage de tampons et analyses de stabilit\u00e9<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-b94fc90 elementor-widget elementor-widget-text-editor\" data-id=\"b94fc90\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>L&rsquo;<b>ITC <\/b>peut \u00e9galement \u00eatre r\u00e9v\u00e9latrice sans liaison au ligand &#8211; par exemple pour l&rsquo;analyse :<\/p><ul><li>de la s\u00e9lection des tampons (par exemple, si un tampon interagit lui-m\u00eame avec la prot\u00e9ine)<\/li><li>de la stabilit\u00e9 thermique via des exp\u00e9riences dites de \u00ab\u00a0chaleur de dilution\u00a0\u00bb.<\/li><li>de syst\u00e8mes auto-associ\u00e9s (par exemple, agr\u00e9gation, dim\u00e9risation).<\/li><\/ul><p>Un exemple pratique :  <strong> <\/strong>Dans une \u00e9tude, l&rsquo;<b>ITC <\/b>a \u00e9t\u00e9 utilis\u00e9e pour tester des prot\u00e9ines recombinantes dans diff\u00e9rentes formulations. Cette exp\u00e9rience a r\u00e9v\u00e9l\u00e9 non seulement des diff\u00e9rences dans l&rsquo;affinit\u00e9 de liaison, mais aussi des indices d&rsquo;instabilit\u00e9 structurelle &#8211; bien avant que des agr\u00e9gations visibles n&rsquo;apparaissent. <\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-8d90305 elementor-widget elementor-widget-spacer\" data-id=\"8d90305\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"spacer.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<div class=\"elementor-spacer\">\n\t\t\t<div class=\"elementor-spacer-inner\"><\/div>\n\t\t<\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-00f172b elementor-widget elementor-widget-heading\" data-id=\"00f172b\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Conclusion<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-260a773 elementor-widget elementor-widget-text-editor\" data-id=\"260a773\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>L&rsquo;<b>ITC <\/b>fournit des donn\u00e9es pr\u00e9cises, robustes et approfondies que les m\u00e9thodes classiques n&rsquo;offrent souvent pas ou seulement de mani\u00e8re indirecte. Pour les utilisateurs de laboratoire, cela signifie un outil qui permet de gagner du temps, de s\u00e9curiser les exp\u00e9riences et de prendre des d\u00e9cisions \u00e9clair\u00e9es. <\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-a3e594d elementor-widget elementor-widget-spacer\" data-id=\"a3e594d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"spacer.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<div class=\"elementor-spacer\">\n\t\t\t<div class=\"elementor-spacer-inner\"><\/div>\n\t\t<\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-efce10d elementor-widget elementor-widget-text-editor\" data-id=\"efce10d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><strong>Bibliographie<\/strong><\/p><p>[1] V. Linkuviene, G. Krainer, W.-Y. Chen, D. Matulis, Calorim\u00e9trie par titrage isotherme pour la conception de m\u00e9dicaments : Pr\u00e9cision des mesures de la constante d&rsquo;enthalpie et de liaison et comparaison des instruments, Analytical Biochemistry 515, 61-64, 2016<\/p><p>[2] H. Su, Y. Xu, Application of ITC-Based Characterization of Thermodynamic and Kinetic Association of Ligands With Proteins in Drug Design, Frontiers in Pharmacology 9, 1133, 2018<\/p><p>[3] L. Baranauskiene, T.-C. Kuo, W.-Y. Chen, D. Matulis, Isothermal titration calorimetry for characterization of recombinant proteins, Current Opinion in Biotechnology 55, 9-15, 2019<\/p><p>[4] N. L. Traulsen, Thermodynamische Analyse von Supramolek\u00fclen durch isothermale Titrationskalorimetrie, Th\u00e8se de doctorat, 2015, Universit\u00e9 libre de Berlin<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t","protected":false},"excerpt":{"rendered":"<p>Dans le d\u00e9veloppement pr\u00e9clinique de m\u00e9dicaments, tout tourne autour de la compr\u00e9hension des interactions mol\u00e9culaires. Qu&rsquo;il s&rsquo;agisse de complexes prot\u00e9ine-ligand, de liaisons anticorps-antig\u00e8ne ou d&rsquo;interactions enzyme-inhibiteur, ce qui compte pour la s\u00e9lection et l&rsquo;optimisation des substances actives biopharmaceutiques, ce n&rsquo;est pas seulement de savoir si une mol\u00e9cule se lie, mais aussi avec quelle efficacit\u00e9, quelle force et pourquoi elle se lie. <\/p>\n","protected":false},"author":3,"featured_media":95691,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"inline_featured_image":false,"footnotes":""},"categories":[187],"tags":[],"class_list":["post-95705","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-connaissance"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.linseis.com\/fr\/wp-json\/wp\/v2\/posts\/95705","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.linseis.com\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.linseis.com\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.linseis.com\/fr\/wp-json\/wp\/v2\/users\/3"}],"replies":[{"embeddable":true,"href":"https:\/\/www.linseis.com\/fr\/wp-json\/wp\/v2\/comments?post=95705"}],"version-history":[{"count":0,"href":"https:\/\/www.linseis.com\/fr\/wp-json\/wp\/v2\/posts\/95705\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.linseis.com\/fr\/wp-json\/wp\/v2\/media\/95691"}],"wp:attachment":[{"href":"https:\/\/www.linseis.com\/fr\/wp-json\/wp\/v2\/media?parent=95705"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.linseis.com\/fr\/wp-json\/wp\/v2\/categories?post=95705"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.linseis.com\/fr\/wp-json\/wp\/v2\/tags?post=95705"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}