{"id":95711,"date":"2025-08-26T08:00:00","date_gmt":"2025-08-26T06:00:00","guid":{"rendered":"https:\/\/www.linseis.com\/?p=95711"},"modified":"2025-09-02T14:42:10","modified_gmt":"2025-09-02T12:42:10","slug":"la-termodinamica-se-une-a-la-biofarmacia-por-que-las-tic-son-cada-vez-mas-relevantes-para-los-laboratorios","status":"publish","type":"post","link":"https:\/\/www.linseis.com\/es\/wiki-es\/la-termodinamica-se-une-a-la-biofarmacia-por-que-las-tic-son-cada-vez-mas-relevantes-para-los-laboratorios\/","title":{"rendered":"La termodin\u00e1mica se une a la biofarmacia &#8211; Por qu\u00e9 las TIC son cada vez m\u00e1s relevantes para los laboratorios"},"content":{"rendered":"\t\t<div data-elementor-type=\"wp-post\" data-elementor-id=\"95711\" class=\"elementor elementor-95711 elementor-95686\" data-elementor-post-type=\"post\">\n\t\t\t\t<div class=\"elementor-element elementor-element-57b4747 e-flex e-con-boxed e-con e-parent\" data-id=\"57b4747\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t<div class=\"elementor-element elementor-element-8fe42cb e-con-full e-flex e-con e-child\" data-id=\"8fe42cb\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div class=\"elementor-element elementor-element-aa11874 e-con-full e-flex e-con e-child\" data-id=\"aa11874\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div class=\"elementor-element elementor-element-2c989c1 e-con-full e-flex e-con e-child\" data-id=\"2c989c1\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div class=\"elementor-element elementor-element-e6ae84c e-con-full e-flex e-con e-child\" data-id=\"e6ae84c\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div class=\"elementor-element elementor-element-8b1d688 e-con-full e-flex e-con e-child\" data-id=\"8b1d688\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-4f88904 elementor-toc--minimized-on-tablet elementor-widget elementor-widget-table-of-contents\" data-id=\"4f88904\" data-element_type=\"widget\" data-e-type=\"widget\" data-settings=\"{&quot;headings_by_tags&quot;:[&quot;h2&quot;],&quot;exclude_headings_by_selector&quot;:[],&quot;no_headings_message&quot;:&quot;No headings were found on this page.&quot;,&quot;marker_view&quot;:&quot;numbers&quot;,&quot;minimize_box&quot;:&quot;yes&quot;,&quot;minimized_on&quot;:&quot;tablet&quot;,&quot;hierarchical_view&quot;:&quot;yes&quot;,&quot;min_height&quot;:{&quot;unit&quot;:&quot;px&quot;,&quot;size&quot;:&quot;&quot;,&quot;sizes&quot;:[]},&quot;min_height_tablet&quot;:{&quot;unit&quot;:&quot;px&quot;,&quot;size&quot;:&quot;&quot;,&quot;sizes&quot;:[]},&quot;min_height_mobile&quot;:{&quot;unit&quot;:&quot;px&quot;,&quot;size&quot;:&quot;&quot;,&quot;sizes&quot;:[]}}\" data-widget_type=\"table-of-contents.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<div class=\"elementor-toc__header\">\n\t\t\t\t\t\t<h4 class=\"elementor-toc__header-title\">\n\t\t\t\t\u00cdndice\t\t\t<\/h4>\n\t\t\t\t\t\t\t\t\t\t<div class=\"elementor-toc__toggle-button elementor-toc__toggle-button--expand\" role=\"button\" tabindex=\"0\" aria-controls=\"elementor-toc__4f88904\" aria-expanded=\"true\" aria-label=\"Abrir la tabla de contenidos\"><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewBox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/div>\n\t\t\t\t<div class=\"elementor-toc__toggle-button elementor-toc__toggle-button--collapse\" role=\"button\" tabindex=\"0\" aria-controls=\"elementor-toc__4f88904\" aria-expanded=\"true\" aria-label=\"Cerrar la tabla de contenidos\"><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewBox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<div id=\"elementor-toc__4f88904\" class=\"elementor-toc__body\">\n\t\t\t<div class=\"elementor-toc__spinner-container\">\n\t\t\t\t<svg class=\"elementor-toc__spinner eicon-animation-spin e-font-icon-svg e-eicon-loading\" aria-hidden=\"true\" viewBox=\"0 0 1000 1000\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M500 975V858C696 858 858 696 858 500S696 142 500 142 142 304 142 500H25C25 237 238 25 500 25S975 237 975 500 763 975 500 975Z\"><\/path><\/svg>\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-a92670d elementor-widget elementor-widget-spacer\" data-id=\"a92670d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"spacer.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<div class=\"elementor-spacer\">\n\t\t\t<div class=\"elementor-spacer-inner\"><\/div>\n\t\t<\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-04a345c elementor-widget elementor-widget-heading\" data-id=\"04a345c\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Introducci\u00f3n<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-b22fc03 elementor-widget elementor-widget-text-editor\" data-id=\"b22fc03\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>En el desarrollo precl\u00ednico de f\u00e1rmacos, todo gira en torno a la comprensi\u00f3n de las interacciones moleculares. Ya sean <b>complejos prote\u00edna-ligando<\/b>, <b>uni\u00f3n anticuerpo-ant\u00edgeno<\/b> o <b>interacciones enzima-inhibidor<\/b>, para la selecci\u00f3n y optimizaci\u00f3n de principios activos biofarmac\u00e9uticos, no se trata s\u00f3lo de si una mol\u00e9cula se une, sino de lo bien, lo fuerte y por qu\u00e9 se une. <\/p><p>Aqu\u00ed es exactamente donde entra en juego <b>la calorimetr\u00eda de valoraci\u00f3n isot\u00e9rmica (ITC<\/b> ): un m\u00e9todo sin etiquetas que funciona en soluci\u00f3n para determinar la afinidad de uni\u00f3n, <a href=\"https:\/\/www.linseis.com\/es\/propiedades\/entalpia\/\" data-auto-event-observed=\"true\"><strong>la entalp\u00eda (\u0394H)<\/strong><\/a>la entrop\u00eda (\u0394S), la energ\u00eda libre (\u0394G) y la estequiometr\u00eda pueden determinarse en un solo experimento. Permite caracterizar las interacciones no s\u00f3lo cualitativamente, sino tambi\u00e9n de forma completamente termodin\u00e1mica, y en condiciones casi fisiol\u00f3gicas.<\/p><p><b>El ITC <\/b>es una potente herramienta para el personal de laboratorio que participa en la caracterizaci\u00f3n de productos biol\u00f3gicos, terapias pept\u00eddicas o prote\u00ednas recombinantes. En las primeras fases de cribado, permite identificar r\u00e1pidamente las mol\u00e9culas con actividad de uni\u00f3n. M\u00e1s adelante, ayuda a optimizar formulaciones, validar sistemas tamp\u00f3n o evaluar par\u00e1metros cr\u00edticos de estabilidad.  <\/p><p>Este art\u00edculo va dirigido a cualquier persona que trabaje con principios activos biofarmac\u00e9uticos en el laboratorio, ya sea en universidades, empresas de nueva creaci\u00f3n o compa\u00f1\u00edas farmac\u00e9uticas establecidas. Te mostramos c\u00f3mo funciona el ITC, cu\u00e1ndo es superior a otros m\u00e9todos y qu\u00e9 debes tener en cuenta para obtener lo mejor de cada experimento. <\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-2a3bb73 elementor-widget elementor-widget-heading\" data-id=\"2a3bb73\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">C\u00f3mo funciona el ITC - y por qu\u00e9 es crucial<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-9873860 elementor-widget elementor-widget-text-editor\" data-id=\"9873860\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><b>La calorimetr\u00eda de valoraci\u00f3n isot\u00e9rmica (ITC<\/b> ) es uno de los pocos m\u00e9todos biof\u00edsicos que miden directamente el calor liberado o absorbido cuando se unen dos mol\u00e9culas. A diferencia de los m\u00e9todos espectrosc\u00f3picos o basados en el etiquetado, como la SPR (espectroscopia de resonancia de plasmones superficiales) o la MST (termoforesis a microescala), la <b>ITC <\/b>funciona completamente sin etiquetado y en soluci\u00f3n, lo que la hace especialmente atractiva para muestras sensibles o nativas. <\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-d7e2d86 elementor-widget elementor-widget-heading\" data-id=\"d7e2d86\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">\u00bfQu\u00e9 ocurre en la probeta?<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-30a2ec8 elementor-widget elementor-widget-text-editor\" data-id=\"30a2ec8\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>El principio es sencillo pero potente: la mol\u00e9cula de analito (por ejemplo, una prote\u00edna) se disuelve en una c\u00e9lula calorim\u00e9trica de alta sensibilidad. La mol\u00e9cula ligando (por ejemplo, un inhibidor o un ant\u00edgeno) se titula mediante una jeringa fina, normalmente en 10-20 peque\u00f1as inyecciones. Cada vez que las mol\u00e9culas se unen, se libera o absorbe calor. El aparato mide este calor como un impulso t\u00e9rmico.   <\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-b4b7eba elementor-widget elementor-widget-heading\" data-id=\"b4b7eba\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">\u00bfQu\u00e9 aporta realmente la ITC?<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-b992738 elementor-widget elementor-widget-text-editor\" data-id=\"b992738\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Se calcula una curva de enlace a partir de los flujos de calor de cada inyecci\u00f3n. El resultado es <\/p><ul><li><strong>Constante de enlace (K)<\/strong>: Indica lo fuerte que es el enlace.<\/li><li><strong>Cambio de entalp\u00eda (\u0394H)<\/strong>: Muestra si el enlace es exot\u00e9rmico o endot\u00e9rmico.<\/li><li><strong>Cambio de entrop\u00eda (\u0394S)<\/strong>: Proporciona informaci\u00f3n sobre los cambios de orden en el sistema.<\/li><li><strong>Energ\u00eda libre (\u0394G)<\/strong>: La expresi\u00f3n termodin\u00e1mica combinada del enlace.<\/li><li><strong>Par\u00e1metro de estequiometr\u00eda (n)<\/strong>: \u00bfCu\u00e1ntos ligandos se unen por mol\u00e9cula diana?<\/li><\/ul><p>Estos par\u00e1metros no s\u00f3lo ayudan a identificar las mol\u00e9culas \u00abhit\u00bb o \u00ablead\u00bb, sino que tambi\u00e9n proporcionan informaci\u00f3n sobre si el enlace se rige por la entrop\u00eda o la entalp\u00eda, lo que es crucial para la optimizaci\u00f3n posterior. Por su combinaci\u00f3n de valor informativo, sencillez y direcci\u00f3n f\u00edsica, <b>el ITC <\/b>es uno de los m\u00e9todos m\u00e1s s\u00f3lidos para caracterizar los enlaces moleculares, especialmente cuando es importante comprender la base energ\u00e9tica. <\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-b7e9dd8 elementor-widget elementor-widget-heading\" data-id=\"b7e9dd8\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">El ITC en uso: aplicaciones t\u00edpicas en biofarmacia<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-dfaba7a elementor-widget elementor-widget-text-editor\" data-id=\"dfaba7a\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Para muchos en el laboratorio surge la pregunta: \u00bfCu\u00e1ndo merece realmente la pena utilizar <b>las TIC <\/b>?<\/p><p>La respuesta: Siempre que el objetivo no sea s\u00f3lo detectar enlaces, sino comprenderlos en detalle. La calorimetr\u00eda de valoraci\u00f3n isot\u00e9rmica no s\u00f3lo proporciona valores de las constantes de enlace para cuestiones biofarmac\u00e9uticas, sino que tambi\u00e9n ofrece profundos conocimientos termodin\u00e1micos que son cruciales para la caracterizaci\u00f3n y optimizaci\u00f3n de los principios activos. <\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-72b3d3e elementor-widget elementor-widget-heading\" data-id=\"72b3d3e\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Interacciones prote\u00edna-ligando: El cl\u00e1sico<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-cca05d2 elementor-widget elementor-widget-text-editor\" data-id=\"cca05d2\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>En particular, en la investigaci\u00f3n inicial de f\u00e1rmacos, el objetivo es identificar a los socios de uni\u00f3n, cuantificar su afinidad y decidir si una estructura principal tiene potencial. El <b>ITC <\/b>puede utilizarse para: <\/p><ul><li>Probar mol\u00e9culas peque\u00f1as (por ejemplo, inhibidores) contra enzimas o prote\u00ednas de transporte<\/li><li>Investigaci\u00f3n de los principios activos pept\u00eddicos y su uni\u00f3n a la diana<\/li><li>Detecci\u00f3n energ\u00e9tica de cambios conformacionales durante la uni\u00f3n<\/li><\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-6ba7a57 elementor-widget elementor-widget-heading\" data-id=\"6ba7a57\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Interacciones anticuerpo-ant\u00edgeno: Comprender la afinidad, no s\u00f3lo medirla<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-77b32c1 elementor-widget elementor-widget-text-editor\" data-id=\"77b32c1\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>El m\u00e9todo proporciona resultados para s\u00f3lidos y l\u00edquidos, as\u00ed como para polvos y pastas, con una gran precisi\u00f3n de medici\u00f3n, lo que lo hace especialmente valioso para el desarrollo de materiales de electrodos innovadores.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-be0b508 elementor-widget elementor-widget-heading\" data-id=\"be0b508\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Consideraciones espec\u00edficas del material y efectos del envejecimiento<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-4451a72 elementor-widget elementor-widget-text-editor\" data-id=\"4451a72\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><b>El ITC <\/b>es un valioso complemento para el desarrollo de terapias basadas en anticuerpos:<\/p><ul><li>Medici\u00f3n precisa de la entalp\u00eda y entrop\u00eda de enlace (\u2192 huellas termodin\u00e1micas)<\/li><li>Evaluaci\u00f3n de la estequiometr\u00eda (por ejemplo, uni\u00f3n monovalente frente a bivalente)<\/li><li>Comparaci\u00f3n de variantes de anticuerpos nativos y modificados en tamp\u00f3n o suero<\/li><\/ul><p>Esto no s\u00f3lo permite seleccionar los mejores candidatos de uni\u00f3n, sino tambi\u00e9n sacar conclusiones sobre los ep\u00edtopos y los mecanismos de uni\u00f3n.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-e16a591 elementor-widget elementor-widget-heading\" data-id=\"e16a591\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Desarrollo de la formulaci\u00f3n: cribado de tampones y an\u00e1lisis de estabilidad<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-b94fc90 elementor-widget elementor-widget-text-editor\" data-id=\"b94fc90\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><b>La ITC <\/b>tambi\u00e9n puede ser informativa sin la uni\u00f3n del ligando, por ejemplo para el an\u00e1lisis:<\/p><ul><li>Selecci\u00f3n del tamp\u00f3n (por ejemplo, si un tamp\u00f3n interact\u00faa con la prote\u00edna)<\/li><li>de la estabilidad t\u00e9rmica mediante los llamados experimentos de \u00abcalor de diluci\u00f3n\u00bb.<\/li><li>de sistemas autoasociados (por ejemplo, agregaci\u00f3n, dimerizaci\u00f3n).<\/li><\/ul><p>Un ejemplo de la pr\u00e1ctica:  <strong> <\/strong>En un estudio, se utiliz\u00f3 <b>el ITC <\/b>para probar prote\u00ednas recombinantes en diferentes formulaciones. Esto revel\u00f3 no s\u00f3lo diferencias en la afinidad de uni\u00f3n, sino tambi\u00e9n indicios de inestabilidades estructurales, mucho antes de que se produjeran agregaciones visibles. <\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-8d90305 elementor-widget elementor-widget-spacer\" data-id=\"8d90305\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"spacer.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<div class=\"elementor-spacer\">\n\t\t\t<div class=\"elementor-spacer-inner\"><\/div>\n\t\t<\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-00f172b elementor-widget elementor-widget-heading\" data-id=\"00f172b\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Conclusi\u00f3n<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-260a773 elementor-widget elementor-widget-text-editor\" data-id=\"260a773\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><b>El ITC <\/b>proporciona datos precisos, s\u00f3lidos y profundos que los m\u00e9todos convencionales a menudo no ofrecen, o s\u00f3lo indirectamente. Para los usuarios de laboratorio, esto significa: una herramienta que ahorra tiempo, asegura los experimentos y permite tomar decisiones bien fundadas. <\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-a3e594d elementor-widget elementor-widget-spacer\" data-id=\"a3e594d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"spacer.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<div class=\"elementor-spacer\">\n\t\t\t<div class=\"elementor-spacer-inner\"><\/div>\n\t\t<\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-efce10d elementor-widget elementor-widget-text-editor\" data-id=\"efce10d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><strong>Bibliograf\u00eda<\/strong><\/p><p>[1] V. Linkuviene, G. Krainer, W.-Y. Chen, D. Matulis, Calorimetr\u00eda de valoraci\u00f3n isot\u00e9rmica para el dise\u00f1o de f\u00e1rmacos: Precisi\u00f3n de las mediciones de entalp\u00eda y constante de uni\u00f3n y comparaci\u00f3n de los instrumentos, Analytical Biochemistry 515, 61-64, 2016<\/p><p>[2] H. Su, Y. Xu, Application of ITC-Based Characterisation of Thermodynamic and Kinetic Association of Ligands With Proteins in Drug Design, Frontiers in Pharmacology 9, 1133, 2018.<\/p><p>[3] L. Baranauskiene, T.-C. Kuo, W.-Y. Chen, D. Matulis, Calorimetr\u00eda de valoraci\u00f3n isot\u00e9rmica para la caracterizaci\u00f3n de prote\u00ednas recombinantes, Current Opinion in Biotechnology 55, 9-15, 2019<\/p><p>[4] N. L. Traulsen, An\u00e1lisis termodin\u00e1mico de supramol\u00e9culas mediante calorimetr\u00eda de valoraci\u00f3n isot\u00e9rmica, tesis, 2015, Universidad Libre de Berl\u00edn.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t","protected":false},"excerpt":{"rendered":"<p>En el desarrollo precl\u00ednico de f\u00e1rmacos, todo gira en torno a la comprensi\u00f3n de las interacciones moleculares. Ya sean complejos prote\u00edna-ligando, uni\u00f3n anticuerpo-ant\u00edgeno o interacciones enzima-inhibidor, para la selecci\u00f3n y optimizaci\u00f3n de principios activos biofarmac\u00e9uticos, no se trata s\u00f3lo de si una mol\u00e9cula se une, sino de lo bien, lo fuerte y por qu\u00e9 se une. <\/p>\n","protected":false},"author":3,"featured_media":95697,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"inline_featured_image":false,"footnotes":""},"categories":[364],"tags":[],"class_list":["post-95711","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-wiki-es"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.linseis.com\/es\/wp-json\/wp\/v2\/posts\/95711","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.linseis.com\/es\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.linseis.com\/es\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.linseis.com\/es\/wp-json\/wp\/v2\/users\/3"}],"replies":[{"embeddable":true,"href":"https:\/\/www.linseis.com\/es\/wp-json\/wp\/v2\/comments?post=95711"}],"version-history":[{"count":0,"href":"https:\/\/www.linseis.com\/es\/wp-json\/wp\/v2\/posts\/95711\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.linseis.com\/es\/wp-json\/wp\/v2\/media\/95697"}],"wp:attachment":[{"href":"https:\/\/www.linseis.com\/es\/wp-json\/wp\/v2\/media?parent=95711"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.linseis.com\/es\/wp-json\/wp\/v2\/categories?post=95711"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.linseis.com\/es\/wp-json\/wp\/v2\/tags?post=95711"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}