GSA PT 1000 - Gravimetric Sorption Analyzer

High End Pressure Sorption Measurements

GSA PT 1000 - Gravimetric Sorption Analyzer

Gravimetric Sorption Analyzer Series - Linseis GSA PT 1000:

Linseis offers a wide range of Gravimetric Sorption Analyzers. Our integrated solution offers the ability to independently software control the pressure, temperature and gas dosing. Our GSA PT 1000 line is based on the well proven linseis microbalance design. This ultra sensitive microbalance is available in two version 0,1 / 1 ug for 5 / 25 g sample weight. A number of environmental chambers are available for operations from -150 up to 1800°C and UHV (ultra high vacuum) to 350 bar. An optional TG-DSC Thermogravimetry – Differential Scanning Calorimetry measuring head allows the simultaneous determination of weight change and caloric reactions in one run. Optional gas and vapor dosing systems as well as residual gas analysis is available.

 

    Model:  GSA PT 1000 HP1 GSA PT 1000 HP2
    Temperature range*: RT up to 1100°C RT up to 1400/1800°C
    Max. pressure: max. 150 bar max. 50 bar
    Vacuum: 10E-4 mbar 10E-4 mbar
    TGA:
    Max. sample mass: 2/15/100g 2/15g
    Resolution:
    0.1/0.5/10 µg 0.1/0.5 µg
    DSC:
       
    DSC resolution:0.3/0.4/1 µW0.3/0.4/1 µW
    DSC sensors: E, K, S, C E, K, S, C
    DTA:   
    DTA sensitivity: undefined  undefined 
    Options: Pressure controlable Gas Mixing System (MFC´s) Pressure controlable Gas  Mixing System (MFC´s) 
    Atmosphere: inert, oxid.**, red., vac.  inert, oxid.**, red., vac.

    * different heaters 

    ** not possible with Graphite heater

      All LINSEIS thermo analytical instruments are PC controlled. The individual software modules exclusively run under Microsoft® Windows® operating systems. The complete software consists of 3 modules: temperature control, data acquisition and data evaluation. The 32 bit software incorporates all essential features for measurement preparation, execution, and evaluation of a STA measurement. Thanks to our specialists and application experts, LINSEIS was able to develop comprehensive easy to understand user friendly application software.

      General Features

      • Program capable of text editing
      • Data security in case of power failure
      • Thermocouple break protection
      • Repetition measurements with minimum parameter input
      • Evaluation of current measurement
      • Curve comparison up to 32 curves
      • Storage and export of evaluations
      • Export and import of data ASCII
      • Data export to MS Excel
      • Multi-methods analysis (DSC TG, TMA, DIL, etc.)
      • Zoom function
      • 1 and 2 derivation
      • Programmable gas control
      • Statistical evaluation package
      • Free scaling

        Application Areas

        • Gas Sorption Analysis
        • Sorption Enthalpies (Simultaneous TG/DSC-Sensor)
        • Density Determination
        • Gas Storage
        • Zeolites
        • Catalysts
        • In-situ Gas Analysis (FTIR, Raman, ELIF)
        • Kinetic Analysis
        • Corrosive Atmospheres - Magnetic Suspension Balance
        • Adsorption Isotherms (BET Surface Analysis)
        • TPD, TPO, TPR measurements (-196 to 1800 °C)


        TPD, TPO and TPR measurements:

        The distribution and relative strength of acid sites in zeolithes are important indicators of its catalytic properties. The acidity of zeolithes can be accurately measured with the temperature programmed desorption (TPD) of a base from the zeolithe surface. The Linseis gravimetric Sorption Analyzers are useful tools for characterizing TPD, TPO or TPR profiles.

        The figure below shows the chemidesorption of ammonia from a zeolithe catalyst surface. Weakly bound ammonia molecules are desorped between 100 and 250 °C. Between 260 and 500 °C strongly bound ammonia is desorped. The amounts of desorped ammonia can be quantitatively measured, i.e. it is possible to quantitatively identify the number of strong and weak acid sites present in the sample.


        In-Situ FTIR:

        In-situ FTIR measurement during CO2 gasification of an anthracite in a TGA system (sample temperature: 1100°C, pure CO2 atmosphere [gas flow rate: 20 ml/min at 273 K, 0.013 bar] during FTIR measurement, FTIR measurement: 30 s, CO absorption at 4300 cm-1, CO2 absorption at 4900 cm-1).

          Here is a short extract of our available accessories:

            • Various gas boxes: manual, semi-automatic and MFC regulated
            • Steam generator
            • Pressure control
            • Wide range of crucibles (gold, silver, platinum, aluminum, Al2O3, graphite, tungsten, stainless steel (high pressure), etc.)
            • Various rotary and turbo-molecular pumps