Linseis Logo Small

SR10 Low Cost Industrial Pen Recorder


Horizontal Rule

The SR10 low cost industrial pen recorder

Horizontal Rule

The SR10 is a panel-mounted digital recorder that features better display visibility, smaller size and weight, and higher cost performance, in order to meet stricter industrial requirements. The recorder embodies Yokogawa's know-how built up over the years, and is supremely reliable for continuous monitoring in industrial applications.

Horizontal Rule Specifications Horizontal Rule


Input Section

Measurement Points:

1,2, or 3 pens, or 6 dot
Measurement Interval: Pen models: 250 ms/channel;
Dot model: 10 s/6 dots (max)
Input Type: DCV (DC Voltage), TC (thermocouple), or
RTD (resistance temperature detector (for dot model only)
Display Section

Display Method:

LED array display (2small and 5 large digits, each comprising 7 segments of LEDs)
Digital Display: AUTO: indicates the channel number, alarm type and measured value, in the order of channel numbers, and updates the readings every 2 seconds.
MAN: indicates the channel number, alarm type and measured value only for the selected channel.
OFF: provides no readings.
Other On-Screen Display: RCD recording-in-progress and ALM alarm common indicators
Recording Section

Recording Method:

Pen Models: Disposable felt-tip pens
Dot Model: 6-color wire-dot recording
Effective Chart Width: 100mm
Chart Length: 16m (Z-fold chart)
Step Response: Pen Models: 2 s, as per IEC 1143 (95% response)
Recording Interval: Pen Models: Channel-by channel continuous recording
Dot Model: 6 dots/30s (max)
-Can be set by selecting between AUTO and FIX modes.
AUTO: determines the analog recording interval in conjunction with the chart speed.
FIX: sets the recorder so it records data at the shortest analog recording interval.
Chart Speed: Pen Models: 10 to 6,000 mm/h (21 steps)
Dot Model: 10 to 1,200 mm/h (18 steps)
Recording colors: Pen Models: first pen - red; second pen - green; third pen - blue
Dot Model: Ch.1 - purple; Ch.2 - red; Ch.3 - green; Ch.4 - blue; Ch.5 - brown; Ch.6 - black
Alarm Function

Number of levels:

2 levels maximum for each channel (selected from upper and lower limits)
Type of Alarm: Upper and lower limits
Indication: Type of alarm raised, and common "ALM" indication
Number of outputs: 2 or 4 (optional; configurable to a logical OR output or energized or de-energized contact outputs)
Power Supply Section

Rated Supply Voltage:

100 to 240V AC (automatically selected)
Rated Power Supply Frequency: 50/60 Hz (automatically selected)
Other Functions

Thermocouple Burnout:

The recorder detects burnouts, channel by channel, if the thermocouple input becomes open-circuited. The selection between upward/downward scale overshoot affects all of the channels.
Linear Scaling: In the DCV range, the recorder allows arbitrary scaling for a given input voltage from -19,999 to +20,000.
Offset Function: Allows arbitrary correction to the DCV,TC and RTD ranges and their scale values, where the range of correction is +/- 10% of the recording span.
Compliance with International Standards

Safety Standards:

CSA22.2 No. 1010.1 and EN61010-1
EMC Standards: EMI: EN55011 Group Class A; EMS: EN50082-2
Standards for Dust/Splash proof doors: DIN 40050-IP54