![]() Pressure Sensor
Recorder Specifications |
Temperature Pressure RecorderUniversal Series CR4 with KTP KitMultifunction Chart Recorders The CR4 with KTP measures and records temperature and pressure simultaneously. It is ideal for solving intermittent compressor problems. Comes complete with independent precision pressure and temperature sensors. Sensor SpecificationsTemperature Sensor
|
Dual Pressure RecorderUniversal Series CR4 with KPP KitMultifunction Chart Recorders Measure and record two pressures simultaneously. Record information on a 6 inch circular chart. Each pen is uniquely colored to maximize chart readability. The full function alarm feature can be set to sound an audible signal when the pressure has exceeded an upper or lower limit. The CR4 KPP comes complete with two pressure sensors, connecting cable and adapter. Sensor SpecificationsPressure Sensors (2 pcs.)
|
Recorder Specifications |
Recorder Specifications |
Temperature, Humidity, Dew Point RecorderUniversal Series CR4 with KTH KitMultifunction Chart Recorders The CR4 with KTH allows for precision measurement of temperature, humidity and dew point. Recordings are displayed digitally as well as on a paper chart. Comes complete with combination temperature, humidity sensor. Sensor SpecificationsTemperature/Humidity Sensor
|
Dual Temperature RecorderUniversal Series CR4 with KTT KitMultifunction Chart Recorders The CR4 with KTT allows for two independent temperature measurements. It is perfect for use in refrigerators, freezers, indoor-outdoor recording, etc. Comes complete with two precision temperature sensors, adapter and connecting cable. Sensor Specifications Temperature Sensor
|
Recorder Specifications |
| Temperature and alarm range | -40°F to +130°F (-30°C to +55°C) |
| Relative humidity alarm range | -40°F to +130°F |
| Pressure alarm range | 0-500 PSI (0-35 BAR) |
| Alarm delay range | User selectable - NO DELAY, 10min, 30min, 1hr., and 2hrs. |
| Remote alarm connection | Normally open contacts 48 VAC/DC, 0.1 A resistive load |
| Ambient operating temperature range | +32°F to + 120°F (O°C to +49°C |
| Chart rotation speeds | User selectable - 1.5,3,6,12, and 24hrs, 7 and 31 days |
| Chart speed mode | User selectable - Continuous or single turn |
| Chart speed accuracy | ± 1% |
| Chart diameter | 6" circular chart (15.3 cm), (60 assorted charts supplied) |
| Display | Alphanumeric backlit LCD, 16 characters x2 lines |
| Primary Power | 115 VAC, 50/60Hz (220-240 VAC, 50/60Hz. optional) |
| Alternative power | 12 Volt vehicle operation with optional adapter |
| Battery backup | 8 AA alkaline batteries |
| Battery life | 48 hours continuous operation |